In lap winding, two sides of the same coil are connected to adjacent commutator segments. Lap wound DC machines can handle more current and suitable for low voltage applications. Lap wound machines are associated with a problem of voltage imbalance. Course title: Electrical Machines Course Link: https://www.youtube.com/watch?v=ERLT2Kc6iYw&list=PL9s6YpaXIcJt1IeX3JV1z1j1E9JUi3bFj